Bug ID 928029: Running switchboot from one tenant in a chassis filled with other tenants/blades gives a message that it needs to reboot the chassis

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Fixed In:
17.1.0, 15.1.4, 14.1.3

Opened: Jul 17, 2020

Severity: 2-Critical

Symptoms

Wrong popup message for switchboot popup "This will restart the chassis. Continue?".

Impact

A confusing popup message is displayed.

Conditions

Run "switchboot" command

Workaround

NA

Fix Information

Updated the switchboot popup message "This will restart BIG-IP tenant. Continue?"

Behavior Change

Guides & references