Bug ID 946745: 'System Integrity: Invalid' after Engineering Hotfix installation

Last Modified: Oct 16, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2

Fixed In:
16.1.0, 15.1.3, 14.1.4

Opened: Sep 19, 2020

Severity: 3-Major

Symptoms

The 'tmsh run sys integrity status-check -a -v' or 'tpm-status' commands incorrectly report system integrity status as 'Invalid' even when the system software has not been modified.

Impact

Incorrect presentation of system software status; the status shows INVALID when it is actually valid.

Conditions

This occurs if all of the following conditions are true: -- BIG-IP software v14.1.0 or later version. -- Engineering Hotfix installed on TPM-supported BIG-IP platform. -- The Engineering Hotfix contains a fix for ID893885 (https://cdn.f5.com/product/bugtracker/ID893885.html). -- The Engineering Hotfix contains an updated 'sirr-tmos' package.

Workaround

None.

Fix Information

Trusted Platform Module (TPM) status now shows the correct system integrity status when an Engineering Hotfix is installed.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips