Last Modified: May 17, 2023
Affected Product(s):
F5OS Velos
Known Affected Versions:
F5OS-C 1.1.0, F5OS-C 1.1.1
Fixed In:
F5OS-C 1.1.2
Opened: Mar 27, 2021 Severity: 3-Major
The output of the 'show partitions' command should display the current operational status (disabled, running, starting, stopping, failed, etc.) for each partition instance. In some cases, the displayed status is incorrect.
The user will be misled about the system state.
When the chassis has multiple partitions, and there are gaps in the partition IDs, the internal state tracking can fail to record and report the partition state, typically showing that a partition is 'failed', when it is actually operating normally.
None
The operational state monitoring has been fixed.