Bug ID 1029585: Use of ha-sync script may cause platforms in a sync-failover device group to fall out of sync

Last Modified: Nov 07, 2022

Bug Tracker

Affected Product:  See more info
BIG-IP SSLO(all modules)

Known Affected Versions:
15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1

Fixed In:
17.0.0, 16.1.2.2, 15.1.6.1

Opened: Jun 29, 2021
Severity: 3-Major

Symptoms

Following the use of the ha-sync script on platforms in a sync-failover device group to become out of sync.

Impact

Both platforms in the sync-failover device group to fall out of sync. Forcing the admin to perform a device-group sync operation.

Conditions

This can occur following the use of the ha-sync script.

Workaround

None

Fix Information

None

Behavior Change