Bug ID 1034825: Discovering and importing BIG-IP configurations with objects with the same name

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IQ Config Mgmt Infrastructure(all modules)

Known Affected Versions:
8.1.0

Fixed In:
8.1.0.1

Opened: Jul 20, 2021

Severity: 2-Critical

Symptoms

When adding/discovering BIG-IP devices, configured in a device service cluster, BIG-IQ returns an error similar to the following: Failed to synchronize clustered devices; reason: Device sync failed from device bigip1.example.com (10.30.40.100) to device bigip2.example.com (10.30.40.101): working-config target object sender failed: Duplicate item. Key already exists: partition : Common, deviceReference : /mgmt/shared/resolver/device-groups/cm-adccore-allbigipDevices/devices/f9c47c54-a1d5-5a65-97f2-334457840585, name : HTTPServer.

Impact

BIG-IQ is unable to discover the BIG-IP device.

Conditions

This happens when: 1) You are running BIG-IQ V8.1.0 base 2) You import a BIG-IP device that is configured in a device service cluster. 3) More than one object in the BIG-IP configuration has the same name. For example, both an LTM virtual server and network route shared the name: HTTPServer

Workaround

None

Fix Information

BIG-IQ can now manage BIG-IP device objects with the same name in its configuration.

Behavior Change

Guides & references