Bug ID 1037525: Some of the PCie AER severity and types are incorrect in the diagnostic monitoring

Last Modified: May 29, 2024

Affected Product(s):
F5OS Velos(all modules)

Fixed In:
F5OS-C 1.3.0, F5OS-C 1.2.2

Opened: Jul 29, 2021

Severity: 2-Critical

Symptoms

Some AER (Advanced Error Reporting) error type and severity events are displayed incorrectly in the diagnostics monitoring.

Impact

AER errors in diagnostic monitoring could be interpreted incorrectly as a 'Fatal' error.

Conditions

If an AER error occurs, the decoding of the error type and severity as reported in the diagnostic might be incorrect.

Workaround

As there is not a complete mitigation for this, the AER errors are correctly logged in the system logs and can be confirmed by timestamp and device to obtain the correct information

Fix Information

Fixed an issue with incorrect diagnostics reporting.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips