Bug ID 1039833: Raid array status is "undefined"

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4

Opened: Aug 11, 2021

Severity: 4-Minor

Symptoms

When the RAID status changes because a disk fails, the disk is pulled without being removed from the RAID, or when RAID rebuild completes, the new status is not updated to be visible in tmsh.

Impact

'tmsh show sys raid' output might show disk as ok when it has actually failed, or may show the disk as undefined when it is actually ok.

Conditions

Running the command: tmsh show sys raid.

Workaround

None

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips