Bug ID 1060197: MachineTunnel does not communicate with DNS Relay Proxy to stop

Last Modified: Apr 28, 2025

Affected Product(s):
APM-Clients APM(all modules)

Known Affected Versions:
7.2.1.3, 7.2.1.4, 7.2.1.5, 7.2.2, 7.2.2.1, 7.2.2.2, 7.2.3, 7.2.3.1, 7.2.4, 7.2.4.2, 7.2.4.3, 7.2.4.4, 7.2.4.5, 7.2.4.6, 7.2.4.7, 7.2.4.8, 7.2.5

Opened: Nov 08, 2021

Severity: 4-Minor

Symptoms

In a few scenarios, the DNS relay proxy does not close when the machine tunnel goes down, and DNS queries still go through DNS proxy.

Impact

If a client that was using the machine tunnel disconnects and then reconnects, the client may be unable to do DNS lookups.

Conditions

-- Using the Machine tunnel feature

Workaround

Restart the DNS Relay Proxy.

Fix Information

None