Last Modified: Apr 28, 2025
Affected Product(s):
F5OS Velos
Fixed In:
F5OS-A 1.0.1
Opened: Dec 02, 2021 Severity: 1-Blocking
Some of the attributes are not being updated properly and are not reporting values.
As the values are not reported properly, it causes inconsistencies in health status of the attributes.
A few attributes were not being monitored, so their values were not reported. A few of the optic attributes (sfp port groups) have redundant attributes.
None
Updated the background monitoring profile to monitor the attributes. Removed the attributes of 2,3 & 4 lanes for sfp port-groups as they are redundant.