Bug ID 1078433: BIG-IP Next Tenant Management IP address is not reachable after a chassis power cycle.

Last Modified: Jul 11, 2024

Affected Product(s):
F5OS F5OS(all modules)

Opened: Feb 04, 2022

Severity: 2-Critical

Symptoms

After a chassis is restarted during a system reboot or power cycle, the tenant cannot be reached using the management IP address.

Impact

Tenant admins will not be able to perform management operations such as network creation/Application configuration.

Conditions

Primarily during a chassis power cycle, tenant IP addresses cannot be reached.

Workaround

If the tenant is recovered within a certain time period, toggling its state from Partition will fix it. CLI: tenants tenant <name> config running-state configured; commit; exit tenants tenant <name> config running-state deployed; commit; exit

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips