Last Modified: Mar 26, 2023
Affected Product(s):
BIG-IP Velos
Fixed In:
17.1.0
Opened: Jul 25, 2022 Severity: 3-Major
Device DoS thresholds are divided between FPGAs. When there are odd number of TMMs, then values are swapped. Because of this there will be a small increase in allow or drop packets compared with the configured thresholds.
There will be a small increase in allow or drop packets compared with configured thresholds.
- This issue will be seen only in Appliance devices with two ATSEs. - When there are odd number of TMMs running inside the tenant.
Create tenant with vcpu cores as 4,8,12,16 e.t.c which results in even number of tmms.
The FPGA can be configured with correct device DoS threshold configurations.