Last Modified: Aug 28, 2024
Affected Product(s):
F5OS F5OS, Install/Upgrade
Known Affected Versions:
F5OS-C 1.5.0
Fixed In:
F5OS-C 1.6.0, F5OS-C 1.5.1
Opened: Aug 05, 2022 Severity: 2-Critical
After an upgrade of the system controller, the chassis partition went into a failed state. syscon-1-active# show partitions partition default RUNNING BLADE OS SERVICE PARTITION SERVICE STATUS NAME ID VERSION VERSION CONTROLLER STATUS VERSION AGE -------------------------------------------------------------------------------- default 1 1.4.0-4112 1.4.0-4112 1 failed - 5m 2 running 1.4.0-4112 15m
The partition management software goes into a failed state and the chassis partition cannot be managed.
Upgrade to v1.5.0 causes the chassis partition to go into a failed state.
Rebooting the failed controller after upgrade or restarting "vcc partition software manager" service fixes the issue. "docker restart vcc-partition-software-manager"
This issue is not reproducible and will be investigated further.