Bug ID 1210433: Conversion between virtual-wire VLAN and normal VLAN

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP Velos(all modules)

Fixed In:
17.1.0, 15.1.9

Opened: Dec 16, 2022

Severity: 2-Critical

Symptoms

In tenant-based platforms, VLAN can be configured on the tenants. On platforms supported with virtual-wire, adding a virtual-wire would cause a conversion of normal VLAN to virtual-wire VLAN and vice-versa. After conversion, the following error message is displayed. 01070712:3: Internal error, object is not in a folder: type: vlan id: /Common/vlan-11-31. This issue has been fixed with this.

Impact

The tenant will not become operationally up.

Conditions

Virtual-wire enabled tenants to see this issue.

Workaround

None

Fix Information

With the fix, normal VLAN and virtual-wire VLAN can co-exist.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips