Bug ID 1311613: UCS obtained from F5OS tenant with FPGA causes continuous TMM restarts when loaded to BIG-IP

Last Modified: Jul 24, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
14.1.5.4, 14.1.5.6, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 16.1.5, 17.0.0.1, 17.0.0.2, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3

Opened: Jun 23, 2023

Severity: 3-Major

Symptoms

--TMM restarts continuously after loading UCS taken from the F5OS tenant with FPGA hardware.

Impact

Migrations or moving configurations across dissimilar platforms will not be successful.

Conditions

The UCS is taken from F5OS tenant with FPGA hardware (VELOS, r5k, r10k), and loaded to a non-F5OS tenant BIG-IP system (VE, vCMP guest, Hardware)

Workaround

Delete the file /config/tmm_velocity_init.tcl. Use the following example command: rm -fv /config/tmm_velocity_init.tcl

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips