Symptoms

TMM restarts continuously after loading a UCS file that was taken from an F5OS tenant with FPGA hardware.

Impact

Migrations or moving configurations across dissimilar platforms will not be successful.

Conditions

The UCS is taken from an F5OS tenant with FPGA hardware (VELOS, r5k, r10k), and loaded to a non-F5OS tenant BIG-IP system (VE, vCMP guest, Hardware)

Workaround

Delete the file /config/tmm_velocity_init.tcl and reboot the device if necessary. Use the following example command: rm -fv /config/tmm_velocity_init.tcl

Fix Information

None