Bug ID 1342129: Issues with liveness probe during tenant deploy/re-deploy causing incorrect identification of container health status

Last Modified: Apr 28, 2025

Affected Product(s):
F5OS Velos(all modules)

Fixed In:
F5OS-C 1.8.0

Opened: Aug 29, 2023

Severity: 2-Critical

Symptoms

Occasional error messages may appear, indicating unhealthiness during tenant deploy and re-deploy due to liveness probe misidentification.

Impact

These error messages are false indications of an issue. If the tenant is operational, these messages can be disregarded. They should resolve themselves within two hours.

Conditions

The issue may occur during tenant deploy/re-deploy.

Workaround

Ignore the false status report messages.

Fix Information

The issue is resolved by implementing additional checks to ensure that the data remains up-to-date, thereby excluding stale positives from the results.