Bug ID 1361021: The management interface media on a BIG-IP Tenant on VELOS does not match the chassis

Last Modified: Jun 04, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3

Opened: Sep 28, 2023

Severity: 5-Cosmetic

Symptoms

The management interface media on a BIG-IP tenant running on VELOS does not match the media/speed of the management interface on the system controllers. Running 'tmsh show net interface' reports the media of the 1/mgmt interface as "100TX-FD".

Impact

The media is reported as "100TX-FD".

Conditions

BIG-IP tenant running on VELOS.

Workaround

On the VELOS system, while running confd, run the following command to see the correct media settings: show interfaces interface 1/mgmt0

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips