Last Modified: Oct 21, 2024
Affected Product(s):
F5OS (all modules)
Fixed In:
F5OS-A 1.8.0, F5OS-A 1.7.0, F5OS-A 1.5.2
Opened: Oct 12, 2023 Severity: 2-Critical
On the webUI, if a LAG type changes from LACP, an error displays when that LAG type changes back to LACP.
This issue does not affect functionality; however, an unnecessary "Object Already Exist" error pop-up appears.
The error occurs when attempting to change the LAG type on an existing LAG interface to a previously used type. (i.e. Creating a LAG interface with type LACP, changing that type to Static, and then changing it back to LACP)
To avoid the pop-up, change the LAG type to LACP using the CLI in this scenario.
Changing the LAG type on an existing LAG interface to a previously used type no longer triggers an error pop-up on the webUI.