Last Modified: Oct 21, 2024
Affected Product(s):
F5OS Velos
Known Affected Versions:
F5OS-C 1.6.0, F5OS-C 1.6.1, F5OS-C 1.6.2
Fixed In:
F5OS-A 1.8.0
Opened: Nov 27, 2023 Severity: 3-Major
SNMP polling on IF-MIB provides incorrect status and speed of LACP Lag interfaces.
The user will see inappropriate status and speed details when polled for IF-MIB details on SNMP for LACP LAG interfaces.
The issue is seen only on SNMP interface. The correct status and speed display on CLI or GUI.
None
Fixed the issue to display the correct values of LACP LAG interfaces in IF-MIB SNMP polling.