Last Modified: Jun 25, 2025
Affected Product(s):
F5OS F5OS-A, F5OS-C
Known Affected Versions:
F5OS-A 1.5.0, F5OS-A 1.5.1, F5OS-A 1.5.2, F5OS-A 1.5.3, F5OS-A 1.7.0, F5OS-C 1.5.0, F5OS-C 1.5.1, F5OS-C 1.6.0, F5OS-C 1.6.1, F5OS-C 1.6.2
Fixed In:
F5OS-C 1.8.0, F5OS-A 1.8.0
Opened: Jan 24, 2024 Severity: 2-Critical
When attempting to get tenant interface stats, the system displays "Error: application error".
Confd reports the error on the command line and logs the error in platform logs. 2024-01-24T20:12:37.123437567Z: [Error]: confd: msg="Action Point reply error" error="confd error: 'Unknown error', last='Invalid confd_vtype value: 0', errno=5"
The creation or modification of tenants may result in inaccurate handling of historical data by the tenant interface-stats logic. This could lead to the display of an “Error: application error” message when queried. For example: appliance-1# tenants tenant cbip-tenant-b state interface-stats down-sample-to 10 average 10s-avg Error: application error
None
The problem has been resolved in more recent versions of F5OS-A. To resolve it, upgrade to a more recent version of F5OS-A. It will resolve once all interfaces are enabled.