Bug ID 1559509: Incorrect displayed state of blade internal data link

Last Modified: Jan 30, 2025

Affected Product(s):
F5OS Velos(all modules)

Known Affected Versions:
F5OS-C 1.6.2

Fixed In:
F5OS-C 1.8.0

Opened: Mar 08, 2024

Severity: 3-Major

Symptoms

The "ifcfg" TMSTAT table on VELOS blades displays an incorrect state for a blade internal link between FPGAs. The "av.1" link is shown as DOWN regardless of its actual state. This link carries tenant traffic on VELOS blades and its operating state may be relevant when performing diagnostics.

Impact

This issue may incorrectly indicate a breakage in a blade's datapath when there is actually none.

Conditions

The issue is seen on all VELOS blades running a F5OS version that does not have the fix.

Workaround

It is possible to view the correct link state with a lower-level debugging command. From the Linux CLI of a VELOS blade, run the following command to get the current state of the blade's data links. [root@blade-4 ~]# docker exec partition_fpga fpgatool -c "linkscan show"

Fix Information

Corrected a configuration field in fpgamgr code that updates link status.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips