Bug ID 1586265: 100G-LR and 100G-LR4 (Innolight and Coherent) optics can fail to link

Last Modified: Oct 19, 2025

Affected Product(s):
F5OS None(all modules)

Fixed In:
F5OS-C 1.8.1

Opened: May 15, 2024

Severity: 2-Critical

Symptoms

The 100G-LR and 100G-LR4 optics can fail to link on bringup.

Impact

The link is down and can't be used. The link needs to be reset. Reboot or reload the FPGA to re-initialize the front panel link.

Conditions

No known special conditions. This issue can happen when the link is initially brought up.

Workaround

A fix for this issue is in F5OS-C-1.8.1 EHF2 and newer. The fix for this issue is also included in F5OS-C-2.0.0.

Fix Information

Data was being transmitted before the optic had finished its power-up. Fix was to modify the SDK to check optic interrupts and wait until all interrupts are clear before proceeding with RX initialization.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips