Bug ID 1586965: No active instance of ConfD after failover

Last Modified: May 05, 2025

Affected Product(s):
F5OS Velos(all modules)

Fixed In:
F5OS-C 1.8.0

Opened: May 18, 2024

Severity: 2-Critical

Symptoms

Unable to configure VELOS system, ConfD CLI commands fail.

Impact

Unable to configure VELOS system, ConfD CLI commands fail.

Conditions

Rarely, after failover newly active system controller silently transitions to none.

Workaround

Reboot chassis.

Fix Information

In releases with this fix in place, after failover there will be always be an Active instance of ConfD.

Behavior Change