Bug ID 1588101: Any changes made on the BIG-IP Next Central Manager after the BIG-IP Next instance backup will not be reflected on the BIG-IP Next Central Manager once the BIG-IP Next instance is restored.

Last Modified: Feb 11, 2025

Affected Product(s):
BIG_IP_NEXT(CM) TMOS(all modules)

Known Affected Versions:
20.1.0, 20.1.1, 20.2.0, 20.2.1

Opened: May 22, 2024

Severity: 4-Minor

Symptoms

After an instance restore is successful, and all the data present in instance is restored, BIG-IP Next Central Manager still shows incorrect data.

Impact

There are discrepancies between BIG-IP Next Central Manager and the instance.

Conditions

Create a BIG-IP Next Central Manager, and discover an instance. Create an instance backup. Make any changes on the instance using BIG-IP Next Central Manager. For example, create a QKview, modify networks or selfips, or delete application services on the instance using BIG-IP Next Central Manager UI. Restore the instance with the backup file created. The change is reflected only on the instance but not on BIG-IP Next Central Manager. As a result, changes before the backup are not visible on the BIG-IP Next Central Manager UI.

Workaround

None

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips