Last Modified: May 13, 2025
Affected Product(s):
F5OS Velos
Known Affected Versions:
F5OS-A 1.5.0, F5OS-A 1.5.1, F5OS-A 1.5.2, F5OS-A 1.5.3, F5OS-A 1.7.0, F5OS-A 1.8.0
Opened: Jun 20, 2024 Severity: 4-Minor
Is a halt -p command is issues to shutdown an rSeries, it's possible the rSeries reboots instead. Here is the log message that is logged after the the halt -p command is run. platform-mgr[17]: priority="Emerg" version=1.0 msgid=0x104000000000031 msg="Manual intervention in CPU Performance, rebooting the system".
BIG-IP rSeries does not shutdown, it reboots instead.
-- BIG-IP rSeries -- halt -p command is run to shutdown the appliance
Try the halt -p again after the appliance reboots.
None