Bug ID 1599377: BIG-IP rSeries reboots after a halt -p command is run instead of shutting down.

Last Modified: May 13, 2025

Affected Product(s):
F5OS Velos(all modules)

Known Affected Versions:
F5OS-A 1.5.0, F5OS-A 1.5.1, F5OS-A 1.5.2, F5OS-A 1.5.3, F5OS-A 1.7.0, F5OS-A 1.8.0

Opened: Jun 20, 2024

Severity: 4-Minor

Symptoms

Is a halt -p command is issues to shutdown an rSeries, it's possible the rSeries reboots instead. Here is the log message that is logged after the the halt -p command is run. platform-mgr[17]: priority="Emerg" version=1.0 msgid=0x104000000000031 msg="Manual intervention in CPU Performance, rebooting the system".

Impact

BIG-IP rSeries does not shutdown, it reboots instead.

Conditions

-- BIG-IP rSeries -- halt -p command is run to shutdown the appliance

Workaround

Try the halt -p again after the appliance reboots.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips