Last Modified: Oct 19, 2025
Affected Product(s):
F5OS F5OS-A
Known Affected Versions:
F5OS-A 1.1.0, F5OS-A 1.1.1, F5OS-A 1.2.0, F5OS-A 1.3.0, F5OS-A 1.3.1, F5OS-A 1.3.2, F5OS-A 1.4.0, F5OS-A 1.5.0, F5OS-A 1.5.1, F5OS-A 1.5.2, F5OS-A 1.5.3, F5OS-A 1.5.4, F5OS-A 1.7.0, F5OS-A 1.8.0, F5OS-A 1.8.3
Opened: Jun 26, 2024 Severity: 3-Major
If two Murata MW2100 AC PSUs are installed in the system and one is operating with an AC input at or above 100V and the second is operating with an AC input below 100V, then an incorrect PSU mismatch condition may occur. Use the F5OS command "show components" to view voltage details for the PSUs.
An incorrect "PSU mismatch" condition may occur.
- r10000 or r12000-series appliance - Two Murata MW2100 AC PSUs, one with an AC input at or above 100V and the other with an AC input below 100V.
Ensure both Murata MW2100 AC PSUs have input voltage at or above 100V or below 100V.
None