Last Modified: Sep 25, 2024
Affected Product(s):
F5OS Velos
Known Affected Versions:
F5OS-A 1.5.2
Opened: Jul 14, 2024 Severity: 2-Critical
OPT-0054-01, Innolight (TR-PY13L-NF5, Rev ‘R1A’) optic experiencing intermittent link problems when connected to r2000/r4000 Port 5.0. Enter the following command in ConfD to display the optic on port 5.0: show portgroups portgroup 5 Output of the following commands indicate the interface is down and not detected: - show interfaces interface 5.0 - ethtool sfp_5
Port #5 does not become active; speed & duplex are reported as unknown.
Inserting the Innolight “R1A” optic into port #5 of a r2000/r4000.
F5 recommends you use one of the following optics in place of the OPT-0054-01 Innolight rev R1A: - OPT-0054-01 Finisar/IR-VI (FTLF1436P3BCL-F5, Rev ‘RA1’) optic. - OPT-0054-01 Innolight rev R2C To identify the OPT-0054-01 Innolight (TR-PY13L-NF5, Rev ‘R1A’) optic, use the revision number. For more information, refer to the example in K000140617 at https://my.f5.com/manage/s/article/K000140617: Verify the right optics module to install on your F5OS system.
None