Last Modified: Jun 28, 2025
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
17.1.1.3, 17.1.1.4, 17.1.2, 17.1.2.1, 17.1.2.2
Fixed In:
17.5.1
Opened: Jul 29, 2024 Severity: 3-Major
TMM is unable to finish initialization when attaching 9 or more Intel 710/E810 SR-IOV interfaces.
BIG-IP is unable to go into the Active state because TMM restart loop is present.
-- Using 9 or more Intel 710/E810 SR-IOV VFs
Update Mcpd.KeepAliveCount DB variable to 127 and reboot the BIG-IP.
DB variable Mcpd.KeepAliveCount was introduced to keep network connections between TMOS proccesses alive longer. Therefore, TMM would have enough time to finish initializing when attaching 9 or more Intel 710/E810 SR-IOV interfaces.