Last Modified: Oct 19, 2025
Affected Product(s):
F5OS Velos
Known Affected Versions:
F5OS-C 1.8.0, F5OS-C 1.8.1
Fixed In:
F5OS-C 1.8.2
Opened: Aug 08, 2024 Severity: 3-Major
An inconsistency in the actual ready status of the nodes and controllers may be observed after a controller failover.
When looking at output of the controller CLI 'show cluster' command, you may see cluster members that are offline when in actuality they are in the Ready state. This is a temporary condition as the output will be eventually update to the correct data.
On a controller failover, it is possible there could be stale cluster status data on the new active controller that is being written into ConfD before a new poll of that data occurs.
No workaround is necessary as the correct results will be shown on the next data poll.
None