Bug ID 1696157: Container api-svc-gateway crashes after enabling a tenant

Last Modified: Jun 19, 2025

Affected Product(s):
F5OS Velos(all modules)

Known Affected Versions:
F5OS-A 1.8.0

Fixed In:
F5OS-C 1.8.1

Opened: Oct 14, 2024

Severity: 3-Major

Symptoms

The api-svc-gateway container crashes intermittently. The logs contain the following entries appliance-1.chassis.local tcpdumpd-manager[8]: priority="Info" version=1.0 msgid=0x5401000000000095 msg="Interfaces/VLANs were removed. No change to hardware programming needed.". appliance-1.chassis.local Core-helper.Appliance: priority="Err" msgid="0x6501000000000001" msg="Core dumped on Appliance" process="api_svc_gateway" location="/var/shared/core/container/core.system_api_svc.api_svc_gateway.25499.1728690599.core.gz" appliance-1.chassis.local alert-service[9]: priority="Notice" version=1.0 msgid=0x2201000000000029 msg="Received event." event="327680 appliance core-dump EVENT NA 'Core dumped on appliance. process=api_svc_gateway, location=/var/shared/core/container/core.system_api_svc.api_svc_gateway.25499.1728690599.core.gz'

Impact

The api-svc-gateway container crashes.

Conditions

1. Enabling a tenant by changing it's running-state to deployed. 2. Enabling a tenant followed by deleting the tenant from the CLI promptly.

Workaround

None. The api-svc-gateway will restart immediately and tenants will be recovered automatically.

Fix Information

The api-svc-gateway will not crash and tenant will be in the expected state after performing the operations.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips