Last Modified: Jan 17, 2025
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3, 17.1.1.4, 17.1.2, 17.1.2.1
Opened: Jan 07, 2025 Severity: 3-Major
Net stp-globals config-name is reset to default "base mac" in running config, while bigip_base.conf has custom config-name. This behavior is seen after upgrade to v17.1.1.3 and also when reboot the device when its in v17.
Any changes to net stp-globals will revert to default after reboot.
1. Upgrade to v17.1.1.3 2. Reboot the device after changing the config-name in stp-globals.
Configure via startup script after MCPD is found running when the BIG-IP system starts up.
None