Bug ID 1953069: Monitor instance table is not updated with the correct transparent attribute

Last Modified: Dec 01, 2025

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
17.1.2, 17.1.2.1, 17.1.2.2, 17.1.3

Opened: May 20, 2025

Severity: 4-Minor

Symptoms

The monitor instance table shows incorrect information.

Impact

The transparent attribute of a monitor is displayed incorrectly in both GUI and shell.

Conditions

A monitor is attached to a node assigned to a pool. The transparent attribute for such a monitor is toggled between enabled and disabled.

Workaround

Remove the monitor and re-assign

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips