Bug ID 1987113: System uptime misreported when uptime is 7 days or more

Last Modified: Oct 19, 2025

Affected Product(s):
F5OS F5OS-C, Velos(all modules)

Known Affected Versions:
F5OS-C 1.8.0, F5OS-C 1.8.1

Fixed In:
F5OS-C 1.8.2

Opened: Jul 16, 2025

Severity: 3-Major

Symptoms

The "show system uptime" command and uptime reported for controllers and blades in the F5OS GUI will report incorrect uptime values when it has an uptime that is 7 days or more, e.g.: [root@controller-1:Active ~]# f5sh show system uptime NAME UPTIME --------------------------------- controller-1 0d, 21h, 36m, 55s controller-2 3d, 5h, 37m, 27s [root@controller-1:Active ~]# uptime 15:41:54 up 21 days, 21:36, 1 user, load average: 6.73, 7.01, 6.56 [root@controller-1:Active ~]#

Impact

The "show system uptime" command output fails to include the number of weeks of uptime.

Conditions

- VELOS system

Workaround

Log into the system as root and run "uptime" on the appropriate system controller or blade.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips