Last Modified: Dec 13, 2025
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3, 15.1.10.4, 15.1.10.5, 15.1.10.6, 15.1.10.7, 15.1.10.8, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2, 16.1.4.3, 16.1.5, 16.1.5.1, 16.1.5.2, 16.1.6, 16.1.6.1, 17.0.0, 17.0.0.1, 17.0.0.2, 17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3, 17.1.1.4, 17.1.2, 17.1.2.1, 17.1.2.2, 17.1.3
Opened: Dec 10, 2025 Severity: 4-Minor
Running an EUD on a i7800 system may report failed (false) results in the HSB2 SRAM tests, but then summarize the section as PASSED, giving an incorrect impression that the system hardware is healthy. For example: 12 08 2025 20:00:48 MB-HSB2-SRAM0 Data Mismatch Count: 0 12 08 2025 20:00:48 MB-HSB2-SRAM0 Received All Words: False 12 08 2025 20:00:48 MB-HSB2-SRAM1 Data Mismatch Count: 0 12 08 2025 20:00:48 MB-HSB2-SRAM1 Received All Words: False 12 08 2025 20:00:48 MB-HSB2-SRAM2 Data Mismatch Count: 0 12 08 2025 20:00:48 MB-HSB2-SRAM2 Received All Words: False ... Packet Path Test PASSED
System cannot bring up or pass traffic on external interfaces.
The issue has been observed in the field on i7800 systems but may affect a wider group of i7000 series devices.
"Received All Words: False" will qualify the appliance for RMA.
None