Bug ID 2196877: Stale cache info can cause inaccurate tenant orchestration operations

Last Modified: Jul 20, 2026

Affected Product(s):
F5OS F5OS-C(all modules)

Fixed In:
F5OS v2.0.0

Opened: Dec 29, 2025

Severity: 3-Major

Symptoms

- A tenant is showing as deployed, has no running pods. - A tenant that is supposed to be running is not running while a deleted tenant is trying to come up (in terms of pods in the system).

Impact

Tenants may not reflect the latest committed configuration state.

Conditions

Sequence of failover operations on the partition when tenant configuration changes were being processed

Workaround

Failover the partition or recreate the tenant.

Fix Information

Updated standby cache regularly and cleared the stale info before orchestration daemon becomes the active one.

Behavior Change