Bug ID 2251233: SNMP polling over management interface may fail when SNMP v2 trap destinations are configured

Last Modified: Apr 08, 2026

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
17.1.0, 17.1.0.1, 17.1.0.2, 17.1.0.3, 17.1.1, 17.1.1.1, 17.1.1.2, 17.1.1.3, 17.1.1.4, 17.1.2, 17.1.2.1, 17.1.2.2, 17.1.3, 17.1.3.1, 17.5.0, 17.5.1, 17.5.1.2, 17.5.1.3, 17.5.1.4, 17.5.1.5

Opened: Mar 17, 2026

Severity: 3-Major

Symptoms

SNMPv2c polling to the BIG-IP management IP times out when sys snmp v2-traps is configured. Typical symptom from poller: Timeout: No Response from <mgmt-ip>

Impact

Monitoring systems may be unable to poll BIG-IP over the management interface, causing loss of SNMP visibility/telemetry while trap destinations are configured.

Conditions

-- SNMP v2c polling is enabled and in use. -- sys snmp v2-traps has one or more configured destinations.

Workaround

None

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips