Bug ID 420344: BFD does not work with IS-IS in HA pair configuration

Last Modified: Oct 03, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.3.0, 11.4.0, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1

Opened: May 01, 2013

Severity: 2-Critical

Symptoms

When BFD is configured between the HA pair neighbor and the HA pair units, BFD fails to establish a session because the IS-IS routing module uses floating self IP address for establishing adjacency rather than non-floating self IP address.

Impact

BFD cannot be used with IS-IS in HA pair configuration.

Conditions

BFD is used with IS-IS in HA pair configuration.

Workaround

None.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips