Last Modified: Nov 22, 2021
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.4.1
Fixed In:
11.5.0
Opened: Aug 15, 2013 Severity: 3-Major
In a VIPRION Chassis with 4 PB2250 blades, when a PSU is removed from the system the LTM reports "notice chmand[7324]: 012a0005:5: Chassis with 4 blades (1200W) may be inadequately powered - increase active number of power supplies" As the PSU's in VIPRION 4-slot chassis are redundant this is incorrect and should be a "loss of redundancy" warning instead. There should not be a reason in a 2 PSU system to ever see a "insufficient power warning". The current messaging will lead to the conclusion that the system was never redundant to begin with.
Confusion about the power status.
PSU changes.
None.
Fixed an issue with incorrect power reporting.