Bug ID 428876: dtca-bundle.crt file version can be out of sync with config

Last Modified: Jul 13, 2024

Affected Product(s):
BIG-IP Install/Upgrade, TMOS(all modules)

Known Affected Versions:
11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4

Fixed In:
12.1.0, 11.6.3

Opened: Aug 26, 2013

Severity: 3-Major

Symptoms

The version of the dtca-bundle.crt file saved in config filestore can get out of sync with the version noted in the BIG-IP configuration file. When this happens BIG-IP attempts to restore the version from the trash can. If the trash can has been purged then the version can not be restored and configuration does not load, and emits the following error: _identify_jobs_todo:(/Common/dtca-bundle.crt) :Failed: name (/Common/dtca-bundle.crt) No copy in trash-bin to restore from. - sys/validation/FileObject.cpp, line 3064

Impact

This error prevents configuration from loading.

Conditions

This appears to be a timing problem related to saving the BIG-IP configuration.

Workaround

The workaround is to edit the configuration file so that the version number matches the version in file store.

Fix Information

This bug fix reduces the occurrence of this bug but does not eliminate it.

Behavior Change

Guides & references