Bug ID 428976: Moving self IPs between VLANs may disrupt OSPF

Last Modified: Oct 03, 2023

Affected Product(s):
BIG-IP None(all modules)

Known Affected Versions:
11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4

Opened: Aug 27, 2013

Severity: 3-Major

Symptoms

If a self IP is configured for advertisement in OSPF and is moved to a different VLAN, the LSA may be removed from the database and not readded.

Impact

Missing prefix from OSPF.

Conditions

OSPF enabled, self IP moved between VLANs.

Workaround

Remove and readd connected route redistribution, delete and readd the self IP, or clear the OSPF process ("clear ip ospf process" in imish).

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips