Last Modified: Aug 19, 2026
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.5.1, 11.5.1 hf1, 11.5.1 hf2, 11.5.1 hf3, 11.5.1 hf4, 11.5.1 hf5, 11.5.1 hf6, 11.5.1 hf7, 11.5.1 hf8, 11.5.1 hf9, 11.5.1 hf10, 11.5.1 hf11, 11.5.2, 11.5.2 hf1, 11.5.3, 11.5.3 hf1, 11.5.3 hf2
Fixed In:
11.6.0, 11.5.4
Opened: Aug 27, 2013 Severity: 3-Major Related Article:
K15554
For switch based platforms, the bcm56xxd daemon monitors the active/standby state using the failover.bigipunitmask DB variable and if this indicates a transition from Active to Standby, it downs external links and starts a timer for re-enabling the links after a customer-specified delay as per the failover.standby.linkdowntime DB variable.
No support for external link down time on network failover.
This occurs on BIG-IP 2000 series and 4000 series platforms.
None.
External link down time on network failover is now supported on BIG-IP 2000 series and 4000 series platforms. You can find the Link Down Time on Failover option in the GUI under Device Management :: Device Groups :: [device_group_name] :: Failover.