Last Modified: Apr 28, 2025
                                            Affected Product(s):
                                            BIG-IP LTM
                                        
                                            Known Affected Versions:
                                            11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3
                                        
                                Opened: Sep 30, 2013 Severity: 3-Major Related Article: 
K15400                                        
                                
                                    
Active device incorrectly marks pool members down or cycles status between up and down. This occurs with transparent VLAN groups.
This might result in monitor flapping and possible traffic misdirection on the active device.
This occurs when monitors are configured to monitor through two layer2 devices on two different child VLANs. The issue occurs only with a significant amount of monitor traffic (for example, up to 128 nodes each way every second). The configuration might also require occasional broadcast ARP requests that were not known by the active device.
Use translucent vlan-groups instead of transparent.
None