Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.0.0, 11.4.0, 11.4.1
Fixed In:
11.5.0
Opened: Oct 02, 2013 Severity: 3-Major Related Article:
K14812
When setting up trust for sync from the GUI on two devices with different time zones, an error will occur indicating that the system clocks are offset by a large number of seconds.
Initial trust configuration cannot be set up.
This only occurs when devices have different time zones as time of setup.
Use the same time zone (such as UTC) on all devices.
You can now set up sync between devices in two different time zones.