Last Modified: Apr 28, 2025
                                            Affected Product(s):
                                            BIG-IP LTM
                                        
                                            Known Affected Versions:
                                            11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11
                                        
                                            Fixed In:
                                            11.6.0, 11.5.2, 11.4.1 HF9
                                        
                                Opened: Oct 21, 2013 Severity: 3-Major Related Article: 
K15536                                        
                                
                                    
If an device group is configured to perform auto-sync with incremental synchronization enabled, and a number of rapid configuration changes cause a rapid sequence of auto-sync operations, synchronizations may fail, and mcpd may log a message like the following to the LTM log: 0107168e:5: Unable to do incremental sync, reverting to full load for device group
Manual mcpd restart may be required.
- This affects any device group configured with auto-sync enabled with and full-load-on-sync disabled. - A number of rapid configuration changes resulting in a rapid sequence of auto-sync operations.
Disable auto-sync.
Automatic incremental synchronization succeeds even after a large number of synchronization operations in rapid succession.