Last Modified: Jul 18, 2026
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.5.1, 11.5.1 hf1, 11.5.1 hf2, 11.5.1 hf3, 11.5.1 hf4, 11.5.1 hf5, 11.5.1 hf6, 11.5.1 hf7, 11.5.1 hf8, 11.5.1 hf9, 11.5.1 hf10, 11.5.1 hf11, 11.5.2, 11.5.2 hf1, 11.5.3, 11.5.3 hf1, 11.5.3 hf2, 11.5.4, 11.5.4 hf1, 11.5.4 hf2, 11.5.4 hf3, 11.5.4 hf4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.0 hf1, 11.6.0 hf2, 11.6.0 hf3, 11.6.0 hf4, 11.6.0 hf5, 11.6.0 hf6, 11.6.0 hf7, 11.6.0 hf8, 11.6.1, 11.6.1 hf1, 11.6.1 hf2, 11.6.2, 11.6.2 hf1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3
Fixed In:
12.0.0
Opened: Oct 28, 2013 Severity: 3-Major Related Article:
K17514
If the DB variable Persist.WellKnownProxyClass names a deleted but loaded config item in Value List Object, the system posts an error.
The configuration file does not load, and the system posts an error similar to the following: Error 0x1020036 occurred: 01020036:3: The requested value_list (/Common/test_group) was not found.
This occurs when the configuration item was removed from the running config, but exists inside a saved config.
Load the UCS file a second time.
Persist.WellKnownProxyClass referencing missing object no longer fails with object-not-found error.