Bug ID 436813: sync statuses differ when sync config in memory is newer than binary database, and the system is restarted

Last Modified: Oct 03, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6

Opened: Nov 06, 2013

Severity: 5-Cosmetic

Symptoms

Messages for sync statuses differ when there is a sync config in memory that is newer than the one in the binary database, and the system is restarted.

Impact

On one system, the message posted is 'Not All Devices Synced', and on another, 'Changes Pending'. This issue is cosmetic only. The actual sync statuses will be correct.

Conditions

This occurs when set-sync-leader and then issue a bigstart restart before saving the config.

Workaround

Save the configuration on a device before rebooting it.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips