Bug ID 436849: Front panel port link LEDs do not match the bundle configuration state

Last Modified: Nov 22, 2021

Bug Tracker

Affected Product:  See more info
BIG-IP LTM(all modules)

Known Affected Versions:
11.4.1

Fixed In:
11.5.0, 11.4.1 HF10

Opened: Nov 06, 2013
Severity: 1-Blocking

Symptoms

If the default bundling configuration is being used, an incorrect front panel 10 GB/40 GB link LED status might display on first startup following a new install.

Impact

The front panel link LEDs might not match the configuration mode shown by the output of the command tmsh list net interface.

Conditions

This occurs when you use the default bundling configuration.

Workaround

Workarounds for correcting the front panel 10G/40G LED link status display include any command that results in a bcm56xxd daemon restart, whether through a 'bigstart restart bcm56xxd', 'bigstart restart', bundling configuration change, blade reboot, etc.

Fix Information

The front panel link LEDs now match the configuration mode shown by the output of the command tmsh list net interface.

Behavior Change