Last Modified: Jan 18, 2026
Affected Product(s):
BIG-IP APM
Known Affected Versions:
11.5.1
Fixed In:
11.6.0, 11.5.1 HF2
Opened: Nov 21, 2013 Severity: 3-Major Related Article:
K16600
There is an issue affecting backward compatibility with FirePass for EPS.
Browser on the FirePass system freezes on 'Checking running processes...' or similar operation. The BIG-IP system continues to operate as expected.
This occurs when using EPS to communicate between the BIG-IP system and FirePass.
None
There is now backward compatibility with FirePass for EPS, so the browser on the FirePass system no longer freezes on 'Checking running processes'.