Bug ID 440346: Monitors removed from a pool after sync operation

Last Modified: Jul 18, 2026

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.5.1, 11.5.1 hf1, 11.5.1 hf2, 11.5.1 hf3, 11.5.1 hf4, 11.5.1 hf5, 11.5.1 hf6, 11.5.1 hf7, 11.5.1 hf8, 11.5.1 hf9, 11.5.1 hf10, 11.5.1 hf11, 11.6.0, 11.6.0 hf1, 11.6.0 hf2, 11.6.0 hf3, 11.6.0 hf4, 11.6.0 hf5, 11.6.0 hf6, 11.6.0 hf7, 11.6.0 hf8, 11.6.1, 11.6.1 hf1, 11.6.1 hf2, 11.6.2, 11.6.2 hf1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3

Fixed In:
12.0.0, 11.5.2

Opened: Dec 10, 2013

Severity: 3-Major

Related Article: K16265

Symptoms

Monitors might be removed from a pool after sync operation.

Impact

Monitors might be removed from a pool on the devices that received a sync.

Conditions

If devices are in a failover device group, and this group contains a pool with multiple health monitors enabled, then using the 'Overwrite Configuration' option.

Workaround

None

Fix Information

Monitors are no longer removed from a pool on the devices that received a sync.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips