Bug ID 446489: Blade Temperature Status reports on blade other than blade1.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10

Fixed In:
11.6.0

Opened: Jan 28, 2014

Severity: 3-Major

Symptoms

When running 'tmsh show sys hardware' on the Primary blade, the 'Blade Temperature Status' reports a blade other than the Primary. In addition, all other slots under this category are not reported.

Impact

tmsh reports the wrong slot under 'Blade Temperature Status' on the Primary blade.

Conditions

This occurs when running the command 'tmsh show sys hardware' on the Primary blade.

Workaround

Use tmctl -d blade blade_temperature_status_stat for the primary blade.

Fix Information

tmsh now reports the correct slot under 'Blade Temperature Status' on the Primary blade.