Bug ID 447255: Intermittent 'CPU #1 temperature' sensor read faults on BIG-IP 2000-/4000-series

Last Modified: Apr 11, 2024

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.0.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.5.1 HF1, 11.6.1 HF1, 11.5.1 HF2, 11.6.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.6.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.2.1, 11.3.0, 11.4.0, 11.4.1

Fixed In:
11.5.0

Opened: Feb 04, 2014

Severity: 4-Minor

Symptoms

Intermittently, errors similiar to the following may be logged: err chmand[5933]: 012a0003:3: Sensor read fault for CPU #1 temperature : File sensor/LopSensSvc.cpp Line 1322. notice chmand[5933]: 012a0005:5: reinitialize tmstat sensors (num sensors:262). notice chmand[5933]: 012a0005:5: reinitialize tmstat sensors (num sensors:269).

Impact

Single occurrences of the 'Sensor read fault' error indicate that the subsequent scheduled read of this sensor succeeded. Aside from the error logged, there is currently no known impact from this issue.

Conditions

This may occur intermittently when BIG-IP is running on a 2000-/4000-series appliance.

Workaround

None.

Fix Information

Intermittent 'CPU #1 temperature' sensor read faults on BIG-IP 2000-/4000-series are resolved by LBH firmware version 4.04 (ID436673).

Behavior Change

Guides & references